General description (Retrieved 07/2024, SPINNER GmbH)
Note:  Unit specific features depend on installed options. Please see unit pictures for options!

Compact Calibration Kits - all necessary calibration standards in one handy unit

Nowadays, no development, production, testing, or quality control department that deals with RF signals on coaxial lines can afford to dispense with state-of-the-art high-precision equipment. It’s essential to use vector network analyzers (VNAs) in particular with high-precision connectors, terminations, and adapters.

Systematic errors can be fixed by calibrating the VNA. Different calibration standards with defined and known electrical characteristics are applied and compared to identify error coefficients. A technique called vector error correction is used to characterize error terms while applying known standards in order to remove errors from actual measurements and increase the accuracy of the results. A VNA can be calibrated in different ways depending on the required degree of accuracy. The methods used differ in both the number and the type of the calibration standards applied. The most commonly used calibration approaches are OSL (which stands for open-short-load) for single-port measurements and OSLT (for open-short-load-through) for multiple-port measurements. The order of the standards can vary in the designation; for example, the abbreviation SOLT is occasionally used synonymously. 3-in-1 compact calibration kits are used worldwide for the development of RF components for mobile communication, broadcast, radar applications, satellite communication, car and vehicle construction, mechanical engineering and many other industrial applications. The OSL compact calibration kit (3-in-1) DC-6 GHz 7-16 male offers the combination of all necessary calibration standards in one handy unit. It is the optimal and easy solution for a convenient and complete calibration of a network analyser with two or more ports using the OSLT procedure with the calibration standards open circuits (O, open), short circuits (S, short) and fixed loads (L, load). The excellent handling, the ergonomic arrangement of the connectors, the small design and the low weight are highly appreciated by the users.

The OSL compact calibration kit (3-in-1) DC-6 GHz 7-16 male has a characteristic impedance of 50 Ω. It is characterised by very low VSWR and attenuation values as well as best intermodulation properties in the entire operating frequency range from DC to 6 GHz. The test kit has 3 interfaces with 7-16 male.

This product has gold-plated connections and is based on the better quality classes of the IEEE, ICE standards with regard to lower tolerances. SPINNER also uses the term ‘precision’ here to emphasize the suitability for exceptionally high-precision measurements.

The 7-16 connector has become the most widely used coaxial connection system for mobile communication systems, due to its excellent mechanical and electrical properties. In order to achieve the industry leading intermodulation performance SPINNER applies silver-plating on all inner and outer conductor parts of the standard connector. As a supporting measure, we use exclusively non-magnetic materials, and we have minimized the number of RF contact points. The connection is especially suited for transmitting medium or high power indoors and outdoors.

SPINNER RF measurement components meet highest standards

SPINNER has set new standards of accuracy with this product line, which includes a large family of coaxial test equipment with outstanding electrical and mechanical attributes for use in laboratory and production environments. For the production SPINNER applies extremely high standards regarding quality, engineering, materials and manufacturing e.g. DIN EN ISO 9001 - Quality Management, DIN EN ISO 14001 - Environmental Management and ISO 50001:2011 - Energy Management. This enables us to offer compact calibration kits with the best possible performance and lowest possible intermodulation (Low PIM).

RF characteristics

Number of interfaces: 3

Interface type: 7-16 male (50 Ω) per IEC 61169-4

Interface direction: straight

Frequency range: DC to 6 GHz

Power rating, max. LOAD: 500.0 mW

Return loss, min. LOAD: 40 dB @ DC to 6 GHz

Phase deviation, max. OPEN: 1.5 ° @ DC to 6 GHz

Phase deviation, max. SHORT: 1.0 ° @ DC to 6 GHz

DC-resistance LOAD: 50 Ω (±0.5 Ω)

Mechanical characteristics

Inner conductor material / surface coating: CuBe age hardened, CuBe, copper-alloy / gold-plated

Outer conductor material / coating: copper-alloy / gold-plated

Insulation material: cross linked polystyrene

Weight, approx.: 550.0 g

Marking: laser engraving


Please contact us for the unit's datasheet!

Terms & Conditions     

The sale includes equipment ONLY. 
No other parts or accessories are included unless otherwise mentioned in the sales listing. 
 
Goods are sold “as is, where is” basis, EXW Raisio, Finland (Incoterms 2020), if not mentioned otherwise. 

 

 Payment & Pricing

Prices are net prices, VAT 0%. 
Full advance payment unless separately agreed otherwise. 

In case you are:  

  • A private purchaser / consumer inside EU, please note that VAT (tax) will be added to the total price. Tax rate (%) is determined by the destination country, same as given in the delivery address. 

  • A business buyer inside EU (except Finnish companies), please provide us your valid VAT ID and the price stays the same (no VAT added) 

  • Outside EU VAT is not applied 

  • Finnish companies & private consumers tax (VAT 24%) will be added to the price 

Shipping & Handling 

Delivery terms: Ex Works Raisio, Finland (Incoterms 2020) 
Buyer is responsible for taxes, duties and other possible import charges. 

International shipping service 
Parcels: Fedex and DHL  
Pallets: TNT and DHL  

All items are packaged with care to ensure full protection during shipping. 

*All courier shipments are insured based on the unit’s value and not weight* 

Most items are shipped within 2 business days of cleared payment. 
Orders placed after 10 a.m. UTC+2  on Friday will ship the following Monday. 

 

Warranty & Returns

A 5 Star Positive Rating is important to us! 

Contact us within 14 days after receiving the purchased unit to request a refund if you notice any failure (If the item includes warranty). Please explain the failure in details with pictures included and pack the unit to the same box it was delivered to you. We will order a return ticket for the failing unit. We will issue the full refund of the unit price after receiving the unit back to us. Please note that as a buyer you are responsible for the return shipping & handling charges.  

If the product is damaged due to the Buyer's mis-handling or return shipping process, we will not refund, and we will notify eBay for return policy abuse.  

AS-IS items are sold without warranty  
Buyer pays shipping charges for returned items.  

 

Contact Us

Contact us if you have any questions regarding items or shipping. 
Please visit our, EQT-Solutions’ web page to find additional assets.  

Business hours and details: We will reply your message as quickly as we can. 
However, please refer to our business hours in Finland: 8:30 - 16:00. 

Agilent N4431B, RF Electronic Calibration Module (ECal), 9 kHz-13.5 GHz, 4-port, MY46181326 #
€3,000.00
Rohde & Schwarz ZV-Z51, Calibration Unit, 300kHz-8GHz, 4 Port, 3.5mm (f), 50 Ohm
€1,800.00
Hewlett Packard 85054D, Mechanical Type N Calibration Kit DC-18GHz #
€3,200.00
Agilent N4431B, RF Electronic Calibration Module (ECal), 9 kHz-13.5 GHz, 4-port, MY46180549 #
€3,000.00
Agilent N4431B, RF Electronic Calibration Module (ECal), 9 kHz-13.5 GHz, 4-port, MY46181464 #
€3,000.00